Electrical Code Question Of The Day 01 26 2020 Based on the 2020 NEC


“Electrical Code Question Of The Day”

Based on the 2020 NEC






Question:   A 30-ampere outdoor air conditioning or Heat Pump  unit for a dwelling unit requires GFCI protection.

True

False

Answer:   True. In the 2020 NEC, 210.8(F) was added to require GFCI protection for all outdoor outlets for dwellings supplied by branch circuits rated 150 volts to ground or less and 50 amperes or less. The only exceptions are for lighting outlets that are not in crawl spaces and the circuits for the equipment covered in 210.8(A)(3) Exception 3.


If you find any errors or have additional information that would expand on any code, building standards or manufacturer requirements please let me know.



NCW Home Inspections, LLC   is a Licensed Washington State Home Inspection service located in Wenatchee Washington serving Chelan County, Douglas County, Kittitas County, Okanogan County and Grant County Washington and the cities of Wenatchee, Leavenworth, Cashmere, Oroville, Cle Elum, East Wenatchee, Quincy and many more…  