AutomatedBuildings.com

[an error occurred while processing this directive] (Click Message to Learn More)


Understanding Specifications
Parts is parts, so they say
Part 2 of 3

Steven R. Calabrese
Steven R. Calabrese
Control Engineering Corp.

Contributing Editor

A s we left off from last month, we were discussing control systems specifications , where to find them, how they are written, and so on. This month we delve into the second part of the written specification: PART 2 ? PRODUCTS. This part seems to vary substantially among written specifications, so I simply put forth my best efforts, to try and come up with a decent, all-encompassing yet straightforward format and descriptions of each segment.

Articles
Interviews
Releases
New Products
Reviews
Editorial

[an error occurred while processing this directive]

Coming Events
Sponsors
Site Search
Blogs
Archives
Past Issues
Home

[an error occurred while processing this directive]

PROGRAM FEATURES

This segment (if included) lists out some standard HVAC-specific programs that the system is to be capable of implementing. Some of these are listed below:

? Scheduling
? Night setback
? Morning Warmup
? Timed override
? Reset
? Enthalpy changeover
? Demand limiting
? Optimal start/stop

Keep in mind that often these are listed without any regard to the particular project. A project may be such that there is no application for ?reset control?, yet it is listed in the specification for the project. Furthermore, most manufacturers offer these types of programs as standard, and if not, the programming methods today are powerful enough to implement any of these from scratch. If you are reading a specification for the purposes of acquiring a project, then you need not be too concerned with these items. If you are reading the specification for the purposes of designing a project, then these may apply. If a Sequence of Operation and/or a Points List is included in the spec, then refer to those items for application of any of these programs.

SENSORS AND TRANSMITTERS

For this and the remaining segments, rather than spending a bunch of time reprinting the typical contents of this portion of the spec, I will simply list out some of the components normally included. I do however, encourage you to pick up a spec for yourself and review these segments, understand how they?re structured, and note what?s included.

? Space Sensors
? Outside Air Sensors
? Duct Sensors
? Averaging Sensors
? Immersion Sensors
? CO & CO2 Transmitters
? Humidity Transmitters
? Pressure Transmitters
? Air & Water Flow Sensing Devices

SWITCHES AND TWO-STATE CONTROLLERS

? Line Voltage Thermostats
? Humidistats
? Occupancy Sensing Switches
? Current Sensing Switches
? Differential Pressure Switches
? Air Pressure Switches
? Clogged Filter Switches
? Water Pressure Switches
? Water Flow Switches
? Water Level Detectors

SAFETIES AND LIMITS

? Freezestats
? High Limit Static Pressure Switches
? High Limit Duct Humidistats
? Smoke Detectors
? Refrigerant Leak Detectors
? Stand-alone CO detectors

END DEVICES

? Control Dampers
? Damper Actuators
? Control Valve Bodies
? Valve Actuators
? Zone Damper & Zone Valve Actuators

MISCELLANEOUS DEVICES

? Control Enclosures
? Relays and Contactors
? Control Transformers & Power Supplies
? Transducers